331-1KF01 - Signal modules analog | Analog input modules

Order no.

331-1KF01

Type SM 331

General information

Note -
Features 8x AI
13 Bit
Voltage +/- 10 V, +/- 50 mV, +/- 500 mV, +/- 5 V, 0 V ... +10 V
Strom +/- 20 mA, 0/4...20 mA
Resistance thermometer
For 40 pole front connector
SPEED-Bus -

Current consumption/power loss

Current consumption from backplane bus 255 mA
Power loss 1.3 W

Technical data analog inputs

Number of inputs 8
Cable length, shielded 50 m
Rated load voltage -
Current consumption from load voltage L+ (without load) -
Voltage inputs
Min. input resistance (voltage range) 100 kΩ
Input voltage ranges -50 mV ... +50 mV
-500 mV ... +500 mV
-1 V ... +1 V
-5 V ... +5 V
0 V ... +10 V
-10 V ... +10 V
+1 V ... +5 V
Operational limit of voltage ranges +/-0.5% ... +/-0.6%
Operational limit of voltage ranges with SFU -
Basic error limit voltage ranges +/-0.3% ... +/-0.4%
Basic error limit voltage ranges with SFU -
Destruction limit voltage max. 30V
Current inputs
Max. input resistance (current range) 100 Ω
Input current ranges -20 mA ... +20 mA
0 mA ... +20 mA
+4 mA ... +20 mA
Operational limit of current ranges +/-0.5%
Operational limit of current ranges with SFU -
Grundfehlergrenze Strombereiche +/-0.3%
Radical error limit current ranges with SFU -
Destruction limit current inputs (electrical current) max. 40mA
Destruction limit current inputs (voltage) max. 15V
Resistance inputs
Resistance ranges 0 ... 600 Ohm
0 ... 6000 Ohm
Operational limit of resistor ranges +/-0.5%
Operational limit of resistor ranges with SFU -
Basic error limit +/-0.3%
Basic error limit with SFU -
Destruction limit resistance inputs max. 15V
Resistance thermometer inputs
Resistance thermometer ranges Pt100
Ni100
Ni1000
Operational limit of resistance thermometer ranges +/-1K ... +/-1.2K
Operational limit of resistance thermometer ranges with SFU -
Basic error limit thermoresistor ranges +/-0.8K
Basic error limit thermoresistor ranges with SFU -
Destruction limit resistance thermometer inputs max. 15V
Thermocouple inputs -
Thermocouple ranges -
Operational limit of thermocouple ranges -
Operational limit of thermocouple ranges with SFU -
Basic error limit thermoelement ranges -
Basic error limit thermoelement ranges with SFU -
Destruction limit thermocouple inputs -
Programmable temperature compensation -
External temperature compensation -
Internal temperature compensation -
Temperature error internal compensation -
Technical unit of temperature measurement °C, °F, K
Resolution in bit 13
Measurement principle Sigma-Delta
Basic conversion time 61 ms/51 ms / channel
Noise suppression for frequency 50 Hz/60 Hz
Initial data size 16 Byte