GM705S GIMC-4045-US/2OSSD IFM
GM705S GIMC-4045-US/2OSSD IFM
Product characteristics | |||||||
Fail-safe inductive sensor | |||||||
Rectangular, plastics | |||||||
M12 connector | |||||||
Enable zone 4...20 mm; [nf] non-flush mountable | |||||||
Complies with the requirements: EN ISO 13849-1: 2008 category 4 PL e IEC 61508: SIL 3 IEC 62061: SILcl 3 |
|||||||
Application | |||||||
Type of operation | continuous operation (maintenance-free) | ||||||
Electrical data | |||||||
Electrical design | DC PNP | ||||||
Operating voltage [V] | 24 DC (19.2...30 DC) | ||||||
Rated insulation voltage [V] | 30 | ||||||
Current consumption [mA] | < 30 | ||||||
Protection class | III | ||||||
Reverse polarity protection | yes | ||||||
Power-on delay time [s] | 5 | ||||||
Outputs | |||||||
Output function | 2 x OSSD (A1 and A2) | ||||||
Output voltage at 24 V | compatible with EN 61131-2 inputs type 1, 2, 3 | ||||||
Voltage drop [V] | < 2.5; (100 mA) | ||||||
Short-circuit protection | yes | ||||||
Range | |||||||
Enable zone [mm] | 4...20 | ||||||
Safe switching off distance s(ar) [mm] | 45 | ||||||
Reaction times | |||||||
Response time to safety request [ms] | ≤ 50 | ||||||
Response time when approaching the enable zone (enable time) [ms] | ≤ 200 | ||||||
Risk time (response time for safety-related faults) [ms] | ≤ 100 | ||||||
Environment | |||||||
Applications | Class C to EN 60654-1 weatherproof application | ||||||
Ambient temperature [°C] | -25...60, for service life ≤ 87600 h 10...40, for service life ≤ 175200 h |
||||||
Rate of temperature change [K/min] | 0.5 | ||||||
Max. relative air humidity [%] | 5...95, briefly 5...70, permanently |
||||||
Air pressure [kPa] | 80...106 | ||||||
Height above sea level [m] | ≤ 2000 | ||||||
Ionising radiation | not permissible | ||||||
Salt spray | no | ||||||
Protection | IP 65 / IP 67 | ||||||
Tests / approvals | |||||||
EMC | IEC 60947-5-2 | ||||||
Shock resistance | IEC 60947-5-2 | ||||||
Vibration resistance | IEC 60947-5-2 | ||||||
Safety classification | |||||||
Mission time TM [h] | ≤ 175200, (20 years) | ||||||
Safety-related reliability PFHd [1/h] | 2.5E-09 | ||||||
MTTFd [Years] | 1992 | ||||||
DC/CCF/Cat. | 99 % / 100 % / 4 | ||||||
Mechanical data | |||||||
Mounting | non-flush mountable | ||||||
Housing materials | PPE; diecast zinc | ||||||
Weight [kg] | 0.355 | ||||||
Displays / operating elements | |||||||
Display |
|
||||||
Electrical connection | |||||||
Connection | M12 connector; Gold-plated contacts | ||||||
Wiring
|