Product characteristics |
Measured signal converter for temperature sensors |
for Pt100 and Pt1000 measuring elements |
Analogue output 4...20 mA |
Measuring range: -50...300 °C / -58...572 °F |
Factory setting: -50...150 °C |
Electrical data |
Electrical design |
|
DC |
Operating voltage [V] |
|
20...32 DC |
Protection class |
|
III |
Reverse polarity protection |
|
yes |
Outputs |
Output |
|
Analogue output 4...20 mA |
Output function |
|
4...20 mA analogue |
Short-circuit protection |
|
pulsed |
Overload protection |
|
yes |
Analogue output |
|
4...20 mA; Rmax: 300 Ω |
Measuring / setting range |
Measuring range |
|
-50...300 °C |
-58...572 °F |
Factory setting |
|
-50...150 °C |
Accuracy / deviations |
Analogue output [K] |
|
± 0.3 + (± 0.1 % MS) |
Temperature coefficients (in % of the span per 10 K) |
|
0.1 |
Measured value via IO-Link [K] |
|
± 0.3 + (± 0.1 % MS) |
Reaction times |
Power-on delay time [s] |
|
1 |
Integrated watchdog |
|
yes |
Interfaces |
IO-Link device |
Transfer type |
|
COM2 (38.4 kBaud) |
IO-Link revision |
|
1.0 |
Environment |
Ambient temperature [°C] |
|
-25...70 |
Storage temperature [°C] |
|
-40...85 |
Protection |
|
IP 67 |
Tests / approvals |
EMC |
|
EN 61326-1 |
Shock resistance |
|
DIN IEC 68-2-27: |
50 g (11 ms) |
|
Vibration resistance |
|
DIN IEC 68-2-6: |
20 g (10...2000 Hz) |
|
MTTF [Years] |
|
449 |
Mechanical data |
Housing materials |
|
PA PACM 12 (TROGAMID); PET; sealing: FPM (Viton); nut: stainless steel 316L / 1.4404; connector: TPU |
Weight [kg] |
|
0.041 |
Electrical connection |
Connection |
|
M12 connector; Gold-plated contacts |
Wiring
|