Hubner Berlin TDP 0,09 LT-3 DC Tachogenerator

Hubner Berlin TDP 0,09 LT-3 DC Tachogenerator
Ürün Kodu: TDP0,09LT-3 HUBNER
Stok Miktarı: Stok Sorunuz
0 yorum  0 yorum  |  Yorum Yap

Hubner Berlin TDP 0,09 LT-3 DC tachogenerator

Technical data - electrical ratings
Reversal tolerance ≤0.1 %
Linearity tolerance ≤0.15 %
Temperature coefficient ±0.05 %/K (open-circuit)
Isolation class B
Calibration tolerance ±3 %
Climatic test Humid heat, constant
(IEC 60068-2-3, Ca)
Interference immunity EN 61000-6-2
Emitted interference EN 61000-6-3
TDP 0,09
Performance 1.2 W (speed ≥3000 rpm)
Armature-circuit
time-constant
<25 µs
Open-circuit voltage 10...60 mV per rpm
TDPZ 0,09
Performance 2x 0,3 W (speed ≥3000 rpm)
Armature-circuit
time-constant
<8 µs
Open-circuit voltage 10...40 mV per rpm
TDP 0,09, TDPZ 0,09
Technical data - mechanical design
Size (flange) ø85 mm
Shaft type ø6 mm solid shaft
Protection DIN EN 60529 IP 56
Torque 1.5 Ncm
Shaft loading ≤40 N axial
≤60 N radial
Materials Housing: stainless steel / plastic
Shaft: stainless steel
Operating temperature -30...+130 °C
Resistance DIN EN 60068-2-6
Vibration 10 g, 10-2000 Hz
IEC 60068-2-27
Shock 300 g, 1 ms
TDP 0,09
Operating speed ≤10000 rpm
Rotor moment of inertia 0.25 kgcm²
Weight approx. 1.1 kg
Connection Terminal box
TDPZ 0,09
Operating speed ≤9000 rpm
Rotor moment of inertia 0.29 kgcm²
Weight approx. 1.5 kg
Connection 2x terminal box